home *** CD-ROM | disk | FTP | other *** search
/ Netware Super Library / Netware Super Library.iso / nov_info / fyicom / 30dec92.sun < prev    next >
Text File  |  1992-12-08  |  10KB  |  296 lines

  1. FYI:Asynchronous Router with Ven-Tel Modem
  2. FYI
  3.  
  4. (Note: The origin of this information may be internal or external to Novell.  Novell makes every effort within it's means to verify this information.  However, the information provided in this document is FOR YOUR INFORMATION only.  Novell makes no explicit claims to the validity of this information.)
  5.  
  6.           TITLE:Asynchronous Router with Ven-Tel Modem
  7.    DOCUMENT ID#:FYI.S.ARO02
  8.            DATE:02AUG91
  9.         PRODUCT:Asynchronous Router
  10. PRODUCT VERSION:1.2
  11.      SUPERSEDES:NA
  12.  
  13. SYMPTOM
  14.  
  15. NA
  16.  
  17. ISSUE/PROBLEM
  18.  
  19. Ven-Tel reports that the Ven-Tel 9600 Plus modem is different than the Ven-Tel PEP modem in the ARCONFIG of NARB V1.2.
  20.  
  21. Ven-Tel no longer makes the listed PEP modem that had been OEMed from Telebit.  Therefore, Ven-Tel 9600 Plus or 9600 Plus II no longer functions as a modem type of "Telebit/Ven-Tel PEP" in ARCONFIG.
  22.  
  23. SOLUTION
  24.  
  25. To use the newer VenTel modems select modem type "Special Configuration."  Then program the modem to do the dialing (on the originate side) and then program the other modem to answer.
  26.  
  27. The AT commands are the following:
  28.  
  29.     ANSWER SIDE
  30.         AT&F&W1&Y1
  31.         AT\N3\Q3%F2X1V0M0&W1
  32.         (Then after programming the modem.  Execute BRIDGE)
  33.  
  34.     In ARCONFIG, this side is not set for auto connect=NO.
  35.  
  36.     ORIGINATING SIDE
  37.         AT&F&W1
  38.         AT\N3\Q3%F2X1V0M0&W1
  39.         AT&Z1=phone number
  40.         AT*V1=DS1
  41.  
  42. Then make sure the ANSWER side is up first.  Turn this modem on and let the modems connect first.  Then execute BRIDGE after the modems have connected.
  43.  
  44. In ARCONFIG, make sure that this side is set to auto connect=YES.
  45.  
  46. After this is done the NARB/NARR will function.
  47.  
  48.  
  49.  
  50.  
  51. FYI:Asynchronous Router and MultiTech V.32 Modems
  52. FYI
  53.  
  54. (Note: The origin of this information may be internal or external to Novell.  Novell makes every effort within it's means to verify this information.  However, the information provided in this document is FOR YOUR INFORMATION only.  Novell makes no explicit claims to the validity of this information.)
  55.  
  56.           TITLE:Asynchronous Router and MultiTech V.32 Modems
  57.    DOCUMENT ID#:FYI.S.ARO03
  58.            DATE:02AUG91
  59.         PRODUCT:Asynchronous Router
  60. PRODUCT VERSION:1.2
  61.      SUPERSEDES:NA
  62.  
  63. SYMPTOM
  64.  
  65. Modem does not initialize properly
  66.  
  67. ISSUE/PROBLEM
  68.  
  69. Using MultiTech V.32 modems with the Asynchronous Router
  70.  
  71. SOLUTION
  72.  
  73. Some dip switch settings on the bottom of the modem need to be changed.  The following settings worked in a test:
  74.  
  75.         ---------  -----------------
  76.         | |x|x| |  |x| | |x|x|x|x| |
  77.         |--------  -----------------
  78.         |x| | |x|  | |x|x| | | | |x|
  79.         ---------  -----------------
  80.          1 2 3 4    1 2 3 4 5 6 7 8
  81.  
  82. The modem type in ACONFIG was set for "Hayes Compatible."
  83.  
  84.  
  85.  
  86.  
  87. FYI:Asynchronous Router Support
  88. FYI
  89.  
  90. (Note: The origin of this information may be internal or external to Novell.  Novell makes every effort within it's means to verify this information.  However, the information provided in this document is FOR YOUR INFORMATION only.  Novell makes no explicit claims to the validity of this information.)
  91.  
  92.           TITLE:Asynchronous Router Support
  93.    DOCUMENT ID#:FYI.S.ARO04
  94.            DATE:13NOV92
  95.         PRODUCT:Asynchronous Router
  96. PRODUCT VERSION:All versions
  97.      SUPERSEDES:NA
  98.  
  99. SYMPTOM
  100.  
  101. NA
  102.  
  103. ISSUE/PROBLEM
  104.  
  105. Is the NetWare Asynchronous Router a current Novell Product?
  106.  
  107. SOLUTION
  108.  
  109. 1.The Asynchronous Router no longer exists as a separately sold Novell product and is considered obsolete.  However, as a courtesy to owners of NetWare v3.11 and NetWare v2.2  operating systems, the most current version is available for download from NOVLIB Library 9 as ARO.ZIP.
  110.  
  111. 2.Because the Asynchronous Router is not an NLM, an Asynchronous Router cannot be an internal router for NetWare v3.11 operating system.
  112.  
  113. 3.The Asynchronous Router is different in several ways from the earlier Asynchronous Bridge.
  114.  
  115. ■You ACONFIG instead of ARCONFIG.
  116. ■Network addresses must be unique instead of the same.
  117. ■Although essentially the same, it is called a Router rather than a Bridge.
  118. ■From time to time as documented in ARO.ZIP, certain features have been improved.
  119. ■Protected Mode is currently not available.
  120.  
  121. Note:  Although the current Asynchronous Router is somewhat improved over earlier versions it still has the following weaknesses:
  122.  
  123. ■It is very difficult to use modems not listed on the ACONFIG menu.
  124. ■It is very fragile if line noise exists.
  125. ■It is much slower than a high speed synch line and is therefore only practical for light duty transfer of small files.
  126. ■It does not load balance.
  127. ■It will not work on data lines.
  128.  
  129.  
  130.  
  131.  
  132. FYI:Asynchronous Router and US Robotics Modems
  133. FYI
  134.  
  135. (Note: The origin of this information may be internal or external to Novell.  Novell makes every effort within it's means to verify this information.  However, the information provided in this document is FOR YOUR INFORMATION only.  Novell makes no explicit claims to the validity of this information.)
  136.  
  137.           TITLE:Asynchronous Router and US Robotics Modems
  138.    DOCUMENT ID#:FYI.S.ARO06
  139.            DATE:12MAR91
  140.         PRODUCT:Asynchronous Router
  141. PRODUCT VERSION:1.x
  142.      SUPERSEDES:NA
  143.  
  144. SYMPTOM
  145.  
  146. Unable to connect
  147.  
  148. ISSUE/PROBLEM
  149.  
  150. Unable to connect using US Robotics modems.
  151.  
  152. SOLUTION
  153.  
  154. Disabling the ARQ result codes as well as the result code sets has been known to help.
  155.  
  156. Use an Asynchronous communication application to program the modems this way:
  157. AT&A0 (arq result codes are disabled. Suppression of the /ARQ codes doesn't  affect the error control protocol.)
  158.  
  159. ATX0 <--- {changed from at&x0} (basic subset returns these codes):
  160.  
  161.        OK
  162.        CONNECT
  163.        RING
  164.        NO CARRIER
  165.        ERROR
  166.  
  167. Remember to write these into memory at both the receiving and calling modems with the &w parameter.
  168.  
  169.  
  170.  
  171.  
  172. FYI:ROUTEGEN Problems on Fast Machines
  173. FYI
  174.  
  175. (Note: The origin of this information may be internal or external to Novell.  Novell makes every effort within it's means to verify this information.  However, the information provided in this document is FOR YOUR INFORMATION only.  Novell makes no explicit claims to the validity of this information.)
  176.  
  177.           TITLE:ROUTEGEN Problems on Fast Machines
  178.    DOCUMENT ID#:FYI.S.ARO07
  179.            DATE:12NOV91
  180.         PRODUCT:Asynchronous Router
  181. PRODUCT VERSION:All versions
  182.      SUPERSEDES:NA
  183.  
  184. SYMPTOM
  185.  
  186. Missing configuration information
  187.  
  188. ISSUE/PROBLEM
  189.  
  190. When you GEN an Asynchronous Router on a fast machine such as some of the ALRs, ROUTEGEN will sometimes fail to insert vital information such as LAN addresses into your ROUTER.EXE file.
  191.  
  192. SOLUTION
  193.  
  194. Do one of the three options listed below:
  195.  
  196. ■Run DCONFIG against ROUTER.EXE.
  197.     
  198. ■Slow down the machine while running ROUTEGEN.
  199.     
  200. ■Set CMOS to 1 wait state while regenerating.
  201.  
  202.  
  203.  
  204.  
  205. FYI:Asynchronous Router and Multi-Tech V.32 L
  206. FYI
  207.  
  208. (Note: The origin of this information may be internal or external to Novell.  Novell makes every effort within it's means to verify this information.  However, the information provided in this document is FOR YOUR INFORMATION only.  Novell makes no explicit claims to the validity of this information.)
  209.  
  210.           TITLE:Asynchronous Router and Multi-Tech V.32 L
  211.    DOCUMENT ID#:FYI.S.ARO08
  212.            DATE:05JUL92
  213.         PRODUCT:Asynchronous Router
  214. PRODUCT VERSION:1.2B (PTF299.ZIP)
  215.      SUPERSEDES:NA
  216.  
  217. SYMPTOM
  218.  
  219. Unable to see server on other side
  220.  
  221. ISSUE/PROBLEM
  222.  
  223. Configuration:
  224.  
  225. Multi-Tech V.32 L modems
  226.  
  227. The routers on both sides came up fine, and the modems would connect; however, the server on the other side could not be seen.
  228.  
  229. SOLUTION
  230.  
  231. Use the following initialization string:
  232.  
  233.     ATX4&Q1&W
  234.  
  235. In addition, the following to LAPM off and MNP on may also help:
  236.  
  237.     AT#L1
  238.  
  239.  
  240.  
  241.  
  242. FYI:Zoom Modems and Asynchronous Router 1.2B
  243. FYI
  244.  
  245. (Note: The origin of this information may be internal or external to Novell.  Novell makes every effort within it's means to verify this information.  However, the information provided in this document is FOR YOUR INFORMATION only.  Novell makes no explicit claims to the validity of this information.)
  246.  
  247.           TITLE:Zoom Modems and Asynchronous Router 1.2B
  248.    DOCUMENT ID#:FYI.S.ARO09
  249.            DATE:19MAY92
  250.         PRODUCT:Asynchronous Router
  251. PRODUCT VERSION:1.2B
  252.      SUPERSEDES:
  253.  
  254. SYMPTOM
  255.  
  256. Not able to establish a connection
  257.  
  258. ISSUE/PROBLEM
  259.  
  260. Unable to establish a connection using Zoom 9600 v.42bis modems.
  261.  
  262. SOLUTION
  263.  
  264. Use the following initialization string:
  265.  
  266. AT&F&D2&Q0V0E0S0=1
  267.  
  268. Using this string established a connection at 9600 baud.
  269.  
  270.  
  271.  
  272.  
  273. FYI:Asynchronous Router and BPS Rate
  274. FYI
  275.  
  276. (Note: The origin of this information may be internal or external to Novell.  Novell makes every effort within it's means to verify this information.  However, the information provided in this document is FOR YOUR INFORMATION only.  Novell makes no explicit claims to the validity of this information.)
  277.  
  278.           TITLE:Asynchronous Router and BPS Rate
  279.    DOCUMENT ID#:FYI.S.ARO10
  280.            DATE:21JAN91
  281.         PRODUCT:Asynchronous Router
  282. PRODUCT VERSION:1.x
  283.      SUPERSEDES:NA
  284.  
  285. SYMPTOM
  286.  
  287. Failure to initialize
  288.  
  289. ISSUE/PROBLEM
  290.  
  291. Can each of the four ports on a WNIN (or WNIM+) board be configured for a different BPS rate?
  292.  
  293. SOLUTION